Pump Controllers See all Applications

Pump Controllers Banner

Pump controllers control different aspects of your pumps, regardless whether you're using submersible pumps, stormwater pumps, circulator pumps or any other pumps. You keep tabs on how each of your heavy-duty pumps is running and whether your system is operating at your required flow rate.

Kwikflo Pump Controllers are distinctive, highly durable and aesthetically attractive. Used for submersible sewage, stromwater, constant pressure systems, hot water circulation systems and transfer pumping systems.

  • Single Pump Controllers
  • Dual Pump Controllers
  • Enclosures

Single Pump Controllers

Building on the success of the FPC-150 Series Single Pump Controller, the new FPC-150-Advanced version, further enhances the “One controller does it all” concept, while at the same time, makes “simplicity of operation” even more user friendly. Although many unique features of the controller are common to all pumping applications, a number of “system specific” optional features, can be enabled or disabled at the flick of a dip switch.

Applications

Single Pump Controller

Common Features

  • Advanced Micro Processor Control Module
  • Distinctive, Highly durable and aesthetically attractive Electronic Keyboard
  • Circuit Breaker protected Low Voltage Control & Input Circuitry
  • Lockable Main Isolator
  • Individual Pump Isolation
  • Auto/Off/Manual Operation of Both Pumps
  • Thermal Overload Protection of Pump Motors
  • Visual and Audible Alarms c/w Mute Switch
  • LED Indicator Lights for System Status indication
  • IP 65 Weather Proof, Powder Coated Metal Enclosures c/w removable gland plate
  • User friendly, clearly labelled, Din Rail mounted, Input & Output Terminal Connection
  • Individually Serial Numbered and logged for traceablity and product support
  • Owner Operator, Installation & Operation Manual supplied with each controller

Functions

  • Auto Alternation of Pump Duty
  • Provision for 4 digital + 1 Analogue input (typically Low Level, Stop/Start, Standby In and High Level)
  • Delayed Start and Minimum Run Time Feature
  • Maximum Run Time and Auto Alternation Feature
  • Maximum Idle Time Feature, for “pump out” of residual in Pump Well situations
  • Anti Seize/Freeze feature, for Low Use and Seasonal Pumping applications
  • Smart “Auto Silencing” and “Chirp Mode” audible Alarm
  • Delayed Standby Pump Start, avoids two motors starting simultaneously
  • Optional “Time Out” on Manual Pump Mode automatic reset to Auto
  • Lamp, Strobe and Buzzer Test button
  • No Flow/Pressure - Inbuilt Timer feature
  • Level Alarm Delay feature avoiding nuisance tripping
  • User friendly, clearly labelled, Din Rail mounted, Input and Output Terminal Connection
  • Interconnectable with Remote Status Indicator panel, via simple data connection
  • Interconnectable with Building Monitoring System Module, via simple data connection

Operating

This controller can perform control functions for most Single Pump pumping applications. It is more than likely that the control parameters have already been set up for your particular application however; hereunder you will find details of the set up and configuration options.

There are six DIP switches located on the lower side of the control module (diagram), which allows for selecting “mode” and “feature” options, as per the following table:

Single Pump Controller Interface

DIP Switch Position Function
1/2 Off/Off Mode A: Standard typical float switch configuration (Start, Stop and High Level)
Off/On Mode B: Standard configuration plus low level (Start, Stop, High Level and Low Level)
On/Off Mode C: Standard configuration plus Prime Loss enabled, on low level (Input 1)
On/On Mode D: Pressure Pumping configuration (Lead, Lag and Low Pressure)
3 Off N/A For Dual situation only
4 Off Anti-seize timer disabled
On Anti-seize timer 10 seconds every 7 days enabled
5 Off When placed in Manual mode, pump remains in Manual mode
On When placed in Manual mode, after 5 minutes the pump will revert to Auto
6 Off High Level alarm automatically resets upon open circuit of high level input. High level alarm has 15 minutes delay
On High level alarm can only be reset manually. High level alarm has 5 minute delay

Single Pump Controller Drawing

Dual Pump Controllers

Building on the success of the FPC-300 Series Dual Pump Controller, the new FPC-300-Advanced version, further enhances the “One controller does it all” concept, while at the same time, makes “simplicity of operation” even more user friendly. Although many unique features of the controller are common to all pumping applications, many “system specific” optional features, can be enabled or disabled at the flick of a switch.

Applications

Dual Pump Controller

Common Features

  • Advanced Micro Processor Control Module
  • Distinctive, Highly durable and aesthetically attractive Electronic Keyboard
  • Circuit Breaker protected Low Voltage Control & Input Circuitry
  • Lockable Main Isolator
  • Individual Pump Isolation
  • Auto/Off/Manual Operation of Both Pumps
  • Thermal Overload Protection of Pump Motors
  • Visual and Audible Alarms c/w Mute Switch
  • LED Indicator Lights for System Status indication
  • IP 65 Weather Proof, Powder Coated Metal Enclosures c/w removable gland plate
  • User friendly, clearly labelled, Din Rail mounted, Input & Output Terminal Connection
  • Individually Serial Numbered and logged for traceablity and product support
  • Owner Operator, Installation & Operation Manual supplied with each controller

Functions

  • Auto Alternation of Pump Duty
  • Provision for 4 digital + 1 Analogue input (typically Low Level, Stop/Start, Standby In and High Level)
  • Delayed Start and Minimum Run Time Feature
  • Maximum Run Time and Auto Alternation Feature
  • Maximum Idle Time Feature, for “pump out” of residual in Pump Well situations
  • Anti Seize/Freeze feature, for Low Use and Seasonal Pumping applications
  • Smart “Auto Silencing” and “Chirp Mode” audible Alarm
  • Delayed Standby Pump Start, avoids two motors starting simultaneously
  • Optional “Time Out” on Manual Pump Mode automatic reset to Auto

Operating

This controller can perform control functions for most Dual Pump pumping applications. It is more than likely that the control parameters have already been set up for your particular application however; hereunder you will find details of the set up and configuration options.

There are six DIP switches located on the lower side of the control module, which allows for selecting “mode” and “feature” options,as per the following table:

Display

DIP Switch Position Function
1/2 Off/Off Mode A: Standard typical float switch configuration (Start, Stop and High Level)
Off/On Mode B: Standard configuration plus low level (Start, Stop, High Level and Low Level)
On/Off Mode C: Standard configuration plus Prime Loss enabled, on low level (Input 1)
On/On Mode D: Pressure Pumping configuration (Lead, Lag and Low Pressure)
3 Off N/A For Dual situation only
On Operating pump alternates each time a pump start is triggered or after 30 minutes continous running
4 Off Anti-seize timer disabled
On Anti-seize timer 10 seconds every 7 days enabled
5 Off When placed in Manual mode, pump remains in Manual mode
On When placed in Manual mode, after 5 minutes the pump will revert to Auto
6 Off High Level alarm automatically resets upon open circuit of high level input. High level alarm has 15 minutes delay
On High level alarm can only be reset manually. High level alarm has 5 minute delay

Dual Pump Controller Drawing

Enclosure 201

Enclosure 201 - 300H X 200W X 150D
Material Mild Steel Sheet
Material Thickness 1.5mm
Color Epoxy Polyester
Powder Coated
RAL 7035
IP Rating IP65

Features
External door has one lock
Complete with galvanised mounting plate (1.8mm)

Enclosure 201 Side

Enclosure 201 Front

Enclosure 202

Enclosure 202 - 300H X 300W X 150D
Material Mild Steel Sheet
Material Thickness 1.5mm
Color Epoxy Polyester
Powder Coated
RAL 7035
IP Rating IP65

Features
External door has one lock
Complete with galvanised mounting plate (1.8mm)

Enclosure 202 Side

Enclosure 202 Front

Enclosure 102

Enclosure 102 - 400H X 300W X 150D
Material Mild Steel Sheet
Material Thickness 1.5mm
Color Epoxy Polyester
Powder Coated
RAL 7035
IP Rating IP65

Features
External door has one lock
Complete with galvanised mounting plate (1.8mm)

Enclosure 102 Side

Enclosure 102 Front

Enclosure 103

Enclosure 103 - 400H X 300W X 200D
Material Mild Steel Sheet
Material Thickness 1.5mm
Color Epoxy Polyester
Powder Coated
RAL 7035
IP Rating IP65

Features
External door has one lock
Complete with galvanised mounting plate (1.8mm)
Inner Door is attached with spring loaded hinges for quick release

Enclosure 103 Side

Enclosure 103 Front

Enclosure 104

Enclosure 104 - 400H X 400W X 250D
Material Mild Steel Sheet
Material Thickness 1.5mm
Color Epoxy Polyester
Powder Coated
RAL 7035
IP Rating IP65

Features
External door has one lock
Complete with galvanised mounting plate (1.8mm)
Inner Door is attached with spring loaded hinges for quick release

Enclosure 104 Side

Enclosure 104 Front

  • Liquid Level Alarms
  • Undersink & Sullage

FPC-12650 & FPC-12651

The MATelec Liquid Level Alarms are designed to provide warning indication when storage (Effluent, Grey Water or Rain Water etc) tank is either empty or full. Warning indication is determined by a float switch. Warnings are; Audio (buzzer), Visual (LED Pilot Light and/or Strobe). The Buzzer can be muted via a mute button. If not muted the Audible buzzer will automatically silence after 5 minutes. If a continuously sounding audible alarm is required, this can be done by changing the Jumper position on the circuit board (See FIGURE 1). The visual alarms will continue to remain on, until the alarm condition is eradicated. A standard feature of the Level Alarm is a ‘Voltage Free’ (5Amp rated) output for connection to auxiliary devices. Controller can be installed up to 50m from the tank being monitored. Float Switch cabling is ‘safe’, low voltage circuitry.

Liquid Level-Alarms

Undersink & Sullage

In instances where undersink /sullage chamber pump systems are installed, there is often a requirement for a High Level Alarm to provide audible and visual indication. MATelec has further developed this Alarm Panel to provide additional features such as Dishwasher Interlock and Water Supply Interlock.

In the event of High Level the Dishwasher Interlock System immediately isolates power to the Dishwasher, insuring that no further ‘inflow’ to the chamber occurs. Similarly, in the event of a High Level the Valve Interlock System isolates water flow to the sink by way of pulsing a solenoid valve closed, ensuring no further black water is discharged from the sink into the chamber. Another feature of this system is that, in the event of a power failure (the pump not being able to pump), the valve is automatically pulsed closed.

The systems are supplied in ‘Kit Form’ complete with Level Switch, Valve and GPO (for Dishwasher) and no High Voltage connections are required. Common to all systems is the Visual and Audible (which can be muted) alarms.

Part No. Description Valve Type Float Switch Enclosure Type
FPC-12659 Level Alarm c/w Valve Interlock 25mm 9006 NRB
2.5mm Cable
Poly
FPC-12660 Level Alarm c/w Dishwasher Interlock N/A 9006 NRB
2.5mm Cable
Poly
FPC-12661 Level Alarm c/w Valve & Dishwasher Interlock 25mm 9006 NRB
2.5mm Cable
Poly
FPC-12662 Level Alarm c/w Valve &
Dishwasher Interlock & Drip
Tray Moisture Sensor
25mm 9006 NRB
2.5mm Cable
Poly

Level Alarm c/w Valve Interlock

Level Alarm c/w Dishwasher Interlock

Level Alarm c/w Valve & Diswasher Interlock

Level Alarm c/w Valve & Dishwasher Interlock & Drip Tray Moisture Sensor

Contact Form